PES (Polyethersulfone) Membranes
PES Membrane Filter Applications
Blood glucose testing
Food, beverage, and pharmaceutical filtration
I.V. filters
Particulate removal
Serum cholesterol testing
Groundwater testing
PES Membrane Filter Specifications
General
Sterilization: Gamma Irradiation, EtO, Autoclave, Live Steam
USP Class VI Testing: Passed
BSA Protein Binding: ~20 μg/cm2
Extractables: <2%
Max. Operating Temp: 130 °C (266 °F)<
Sealing Compatibility: Ultrasonic, Heat, Radio Frequency, and Insert Molding
Nominal Thickness: 110-150 µm
Performance by Pore Size
0.03 µm | 0.10 µm | 0.20 µm | 0.45 µm | 0.65 µm | 0.80 µm | 1.20 µm | 5.00 µm | |
Flow Rate1 | 5.5 | 11.7 | 33.2 | 58.2 | 95.5 | 117.0 | 143.0 | 186.0 |
Bubble Point (psi) | 90.0 | 70.0 | 50.0 | 35.0 | 21.3 | 13.0 | 11.0 | 6.0 |
Thickness | 110-150 µm | 110-150 µm | 110-150 µm | 110-150 µm | 110-150 µm | 110-150 µm | 110-150 µm |
*Notes:
Flow rate measured with water as mL/min/cm2 at 10 psi (0.7 kg/cm2)