Nylon Membranes

Nylon Membranes

Nylon Membrane Filter Applications

General Filtration

Medical Assays

Food, beverage, and pharmaceutical processing

HPLC Sample Preparation

Sterilize and clarify aqueous and organic solvent solutions

Recommended for use in ASTM D6217: Standard Test Method for Particulate Contamination in Middle Distillate Fules by Laboratory Filtration.

Recommended for use in ASTM D5304: Standard Test Method for Assessing Middle Distillate Fuel Storage Stability by Oxygen Overpressure

Nylon Membrane Filter Specifications

General

USP Class VI TestingPassed
BSA Protein Binding~120 μg/cm2
SterilizationGamma Irradiation, EtO, Autoclave
Max. Operating Temp180 °C (356 °F)
Sealing CompatibilityUltrasonic, Heat, Radio Frequency, and Insert Molding
pH Range3-12
Nominal Thickness65-130 µm

Performance by Pore Size

Nominal Water Flow2(mL/min·cm2)Minimum Water Bubble Point (psi)1
0.10 µm4.070.0
0.20 µm9.950.0
0.45 µm26.930.0
0.65 µm59.318.0
0.80 µm80.513.0
1.20 µm180.011.0
5.00 µm331.06.0

*Notes:

The pressure at which air is first forced through the pores of a membrane saturated with purified water.

Measured at 10psi (0.69bar) differential pressure using purified water at 70°F (21°C).