PTFE Syringe and Vent Filters
PTFE Syringe Filters
PTFE Hydrophobic Syringe Filters
Features:
Highly hydrophobic
Excellent chemical compatibility
Very low extractables
Superior flow performance compared to other hydrophobic membranes
Applications:
Clarification of nonaqueous lab reagents, solvents and samples
Filtration of nonaqueous chromatography samples and mobile phases
Venting and degassing
| Pore Size | Filter Size | Filter Type | Filter Area (cm²) | Holdup Volume (µL) | Housing Material | Housing OD (mm) | Connections | Maximum Pressure (bar) | Recommended Sample Volume (mL) |
| 13mm | Abluo | 0.76 | <50 | Polypropylene | 18 | FLL, MLL | 5.0 | ||
| 17mm | Cameo | 1.40 | <40 | Polypropylene | 22 | FLL, MLL | 5.5 | <12 | |
0.22µm (0.20µm) | 25mm | Abluo | 4.60 | <100 | Polypropylene | 33 | FLL, MLL | 5.0 | |
| 30mm | Cameo | 4.80 | <100 | Polypropylene | 33 | FLL, MLL | 5.5 | <120 | |
| 50mm | Advantec | 19.6 | <3000 | Polypropylene | 65 | FLL, MLL | 3.4 | >100 | |
0.22µm (0.20µm) Sterilized | 50mm | Sterlitech | 19.5 | Polypropylene | 72 | FLL, MLL | 3.0 | ||
| 13mm | Abluo | 0.76 | <50 | Polypropylene | 18 | FLL, MLL | 5.0 | ||
0.45µm | 17mm | Cameo | 1.40 | <40 | Polypropylene | 22 | FLL, MLL | 5.5 | <12 |
| 25mm | Abluo | 4.60 | <100 | Polypropylene | 33 | FLL, MLL | 5.0 | ||
| 30mm | Cameo | 4.80 | <100 | Polypropylene | 33 | FLL, MLL | 5.5 | <120 | |
0.45µm Sterilized | 50mm | Sterlitech | 19.5 | Polypropylene | 72 | FLL, MLL | 3.0 | ||
0.5µm | 50mm | Advantec | 19.6 | <3000 | Polypropylene | 65 | FLL, MLL | 3.4 | >100 |
PTFE Hydrophilic Syringe Filters
Features:
Permanent hydrophilic treatment for ease of use with aqueous solutions
Excellent chemical compatibility including strong acids, bases, and oxidizers
Very low extractables
Applications:
Clarification of aggressive aqueous solvent solutions including amines, ketones, and polar aprotic
Filtration of both aqueous and organic chromatography samples, buffers, and mobile phases
Filtration of strong acids and bases
| Pore Size | Filter Size | Filter Type | Filter Area (cm²) | Holdup Volume (µL) | Housing Material | Housing OD (mm) | Connections | Maximum Pressure (bar) | Recommended Sample Volume (mL) |
| 0.22µm | 13mm | Advantec | 0.90 | <30 | Polypropylene | 17 | FLL, MLL | 3.9 | <10 |
| (0.20µm) | 25mm | Advantec | 4.00 | <100 | Polypropylene | 29 | FLL, MLL | 3.9 | <100 |
| 13mm | Advantec | 0.90 | <30 | Polypropylene | 17 | FLL, MLL | 3.9 | <10 | |
| 0.45µm | 25mm | Advantec | 4.00 | <100 | Polypropylene | 29 | FLL, MLL | 3.9 | <100 |
Vent Filters with PTFE Membranes
Applications
Sterile venting of filling vessels, including culture vessels and CO2incubators</span >
Venting of holding tanks for sterile, distilled water and liquid culture media</span >
Autoclave venting
In-line sterilization and particulate removal from air and gases</span >
Protects vacuum systems from pathogen contamination and vacuum pumps from aerosol corrosion</span >
Sterile gas introduction to bioreactors and culture vessels
Venting of bioreactors, fermentation tanks, and carboys
Filtering aggressive solvents in volumes beyond syringe filter capacity</span >
Protects work area from airborne pathogens and hazardous vacuum pump exhaust or venting</span >
Vent Filters With PTFE Membranes Specifications
| 0.2 µm | 0.45 µm | |
| Membrane Type | Hydrophobic PTFE reinforced with Polypropylene | Hydrophobic PTFE reinforced with Polypropylene |
| Pore Size | 0.2 µm | 0.45 µm |
| Housing | Polypropylene | Polypropylene |
| Connectors | 6 to 12 mm stepped barb or 1/8″ NPT | 7 to 12 mm stepped barb or 1/8″ NPT |
| Filter Area | 19.6 cm2 | 19.6 cm2 |
| Air Flow Rate | 27 L/min at 1 bar | 32 L/min at 1 bar |
| Housing Diameter | 63 mm | 63 mm |
| Housing Length | 53 mm | 53 mm |
| Bubble Point (Ethanol) | 0.6 bar | 0.9 bar |
| Maximum Pressure | 3.5 bar (50 psi) | 3.5 bar (50 psi) |
| Sterilization | Autoclave at 121 °C or EtO. Autoclave up to 10 times | Autoclave at 121 °C or EtO. Autoclave up to 10 times |
| Biosafety | All materials passed USP Class VI testing | All materials passed USP Class VI testing |